California RDA exam · Free practice questions
Five original RDA exam practice questions on sterilization and disinfection, each answered on this page with a rationale and a source.
Last updated 2026-07-25
Question 1 of 5
Answer D: That the package was exposed to the process conditions.
A chemical indicator shows that the package was exposed to the process conditions; only a biological indicator demonstrates that highly resistant spores were killed.
Common trap: a passing chemical indicator never clears a positive spore test and never substitutes for the weekly biological verification.
Question 2 of 5
Answer B: The dry, intact pouch may be used; the damp one must be reprocessed.
Sterility is event-related, not time-related: a dry, intact, sealed package remains sterile, while a wet, torn, or dropped package is contaminated and must be cleaned, repackaged, and re-sterilized.
Common trap: treating a date as an expiration — and treating a recent date as protection against moisture — inverts the rule in both directions.
Question 3 of 5
Answer B: Wiping the disinfectant dry immediately — the surface must be cleaned first, then left wet for the label's full contact time.
The regulation defines cleaning as removing visible soil and debris with water plus a detergent or enzymatic product, and states that "Cleaning must precede any disinfection or sterilization process." That is the entire basis of the spray-wipe-spray (or wipe-discard-wipe) routine: the first pass cleans, the second pass leaves disinfectant sitting on a clean surface for the label's contact time, because "All germicides must be used in accordance with intended use and label instructions." Removing the barrier with gloved hands was correct, and a Cal-EPA registered hospital-grade low- to intermediate-level product is the correct strength for a routine clinical contact surface.
Common trap: Option A inverts the correct order — barriers come off while still gloved, then gloves come off, then hand hygiene. Option C confuses categories: a countertop inside the treatment zone is a clinical contact surface, and floors, walls, and sinks are the housekeeping surfaces. Option D over-escalates; high-level disinfection is for heat-sensitive semi-critical and critical items, never a routine surface requirement.
Question 4 of 5
Answer B: Protect them with disposable impervious barriers, changed between patients and when visibly soiled.
The regulation makes barriers the required answer for one specific category: non-critical items or surfaces that are likely to be contaminated and are built in a way that prevents proper cleaning and disinfection "shall be protected with disposable impervious barriers." The change rule is absolute — "Disposable barriers shall be changed when visibly soiled or damaged and between patients." Impervious means fluid cannot soak through, so plastic sleeves, plastic-backed paper, and plastic wrap qualify.
Common trap: Option C is the quiet failure — plain paper is not impervious, so fluid reaches the surface underneath. Option A downgrades a between-patient requirement to an end-of-day one. Option D invents an exemption that does not exist: every clinical contact surface has exactly two lawful states between patients, covered or cleaned-and-disinfected.
Question 5 of 5
Answer A: Purge or flush for at least 2 minutes at the start of each workday before devices are attached; flush 20 seconds between patients.
16 CCR §1005 requires that at the beginning of each workday the lines and devices be "purged with air, or flushed with water for at least two (2) minutes prior to attaching handpieces, scalers, air water syringe tips, and other devices," and that "The dental unit lines and devices shall be flushed between each patient for a minimum of twenty (20) seconds." The sequence is written into the sentence: the purge or flush happens before devices are attached, not after. The same section separately requires that dental unit waterlines be anti-retractive so fluid is not pulled back up the line.
Common trap: This is a classic stale-prep item — reversing the two numbers is the single most common error on this topic, and option B does exactly that. Option C keeps the right morning number but attaches devices first, which defeats the purpose of purging the line. Option D substitutes a plausible-sounding round number that appears nowhere in the regulation.